I/O Controller PL / 1204 connects 8/12 binary inputs, 8/4 binary outputs and a RS-232/485 serial interface to a network (Terminal server). The serial port as well as the I/O lines are accessible over TCP/IP using the NVT protocol. I/O Controller works with HW VSP - virtual serial port for Windows. I/O Controller supports TCP connections in Client/Server mode, and can inform about changes at the inputs, or characters received at the serial port.
IP Watchdog Lite monitors the functionality of Ethernet connections and devices using the "ping" function. If there is no response within a specified time, its output relay is activated. IP WatchDog Lite contains two relays and monitors two independent connections. Ping requests can be sent and replied to.
IP WatchDog Lite can reset a device, activate an alarm, or initiate a failover to a backup communication link.
Damocles 2404 connects 24 binary inputs (electrically isolated), 4 relay outputs, and one temperature sensor to a TCP/IP network.
Inputs can count pulses. Outputs can be controlled autonomously using a set of conditions, or remotely over the network. The 2404 model is intended for industrial use, and fits on a DIN rail.
It is controlled over a Web/HTML interface, communicates via XML, SNMP, Modbus/TCP and E-mail.
Damocles MINI enables access to 4 binary inputs (for contacts) and 2 relay outputs over an Ethernet network. If the state of a binary input changes, the device can send an e-mail, SNMP trap, activate one of its outputs, or send a text message (SMS) using the supplied SW.
Inputs can count pulses. Outputs can be controlled autonomously using a set of conditions, or remotely over the network. It is controlled over a Web/HTML interface, communicates via XML, SNMP, Modbus/TCP and E-mail.
IP Relay connects 2 relay outputs and a RS-232/485 serial line to a network (Terminal server).
Relay outputs and the serial port can be controlled over TCP using the NVT protocol. Works with HW VSP - virtual serial port for Windows.
A large library of examples in the HWg SDK can be used to develop supporting software.
IP Relay can control 230V / 16A, is intended for industrial use, fits on a DIN rail.
Converts a RS-232 or RS-485 serial line to Ethernet TCP/IP and UDP/IP. The remote serial port can be mapped in Windows to COM7 using the HW VSP (Virtual Serial Port). Typical PortBox applications include remote access to equipment controlled over RS-232 or RS-485, or extending the range of a serial line over the Ethernet.